Quinn Therm QF PIR Insulation Board

Mannok IsoFrame – PIR insulation for Steel/Timber Frame

Foil faced rigid Polyisocyanurate (PIR) insulation, for external cavity walls of conventional timber and steel framed dwellings with a masonry outer leaf. Height restrictions apply in some cases. Mannok IsoFrame may be installed between structural studs. Also, used with insulated dry lining systems and as insulated sheathing or used as part of a system incorporating any combination of these options.

Mannok IsoFrame has been tested to BS EN 1365-1:2012 and BS 476-21:1987 for use with structural steel/timber studs, where a fire resistance of 30 minutes is required. In steel stud construction it has 60 minutes fire resistance.

*Mannok IsoFrame (previously Quinn Therm QW-STFI)

Specification
The wall insulation will be Therm Isoframe manufactured by Therm Ltd, to BS EN 13165-1:2012.
Comprising a rigid Polyisocyanate (PIR) core with low emissivity trilaminate aluminium foil facings.
Low thermal conductivity, minimising the thickness required to achieve the design U-value.
Zero ozone depletion potential (zero ODP) and low global warming potential (GWP)
Achieves an A+ rating when compared to the BRE Green Guide.
To be installed in accordance with the instructions of Therm Ltd. and conditions set out in the BBA Certificate 07/4444.
Performance & Properties
Board size (mm)1200 x 2400
Thickness (mm)20mm – 200mm
Thermal Conductivity (λ)0.022w/mk
FacersLow emissivity foil facers
Core water vapour resistivity≅300MNs/gm
Compressive Strength>150kPa
EdgeButt Joint
Applications
Insulation for Steel/Timber framed cavity wall construction (see BBA Certificate 07/4444 product sheet 10)